Thermodynamics · Subject guide

Thermodynamics, cycles and heat-transfer calculations

Set up thermodynamic states, energy balances and heat-transfer models. Compare ideal cycle results with actual performance and work through stated examples.

Thermodynamics tracks energy, matter and the restrictions on converting heat into work. Heat transfer explains the rate at which thermal energy moves through materials, fluids and radiation fields. A complete problem may require both: an energy balance can tell you the heat required, while a heat-transfer model tells you whether a particular exchanger can provide it.

Begin by drawing the system boundary and naming the states. Without those two choices, quantities such as heat input, efficiency and enthalpy change remain ambiguous.

Select a closed system or a control volume

A closed system follows a fixed quantity of matter. Its boundary can move and energy can cross it, but mass does not. A control volume occupies a region through which mass may enter and leave. A flowing heater, pump or turbine is commonly treated as a control volume.

Choose signs explicitly. This handbook takes heat transfer into a system as positive and useful work leaving it as positive. Other conventions are valid if carried consistently.

For a steady one-inlet, one-outlet device:

Qdot − Wdot = ṁ[(h2 − h1) + (V2² − V1²)/2 + g(z2 − z1)].

Enthalpy packages internal energy and flow-work effects as h = u + pv. Use compatible energy units: the velocity term in SI is J/kg, so divide by 1,000 before combining it with enthalpies expressed in kJ/kg.

The DOE thermodynamics handbook develops state properties, control volumes and the first and second laws.

Establish enough state information

For a simple compressible substance in a single-phase equilibrium region, two suitable independent intensive properties commonly define the state. Pressure and temperature on a saturation line are not independent; an additional phase-fraction description may be needed.

Steam-cycle calculations therefore require a property method, not just a generic “steam constant.” The IAPWS industrial water-and-steam formulation defines a widely used basis. The NIST fluid database provides state-dependent properties for several fluids. Check phase, reference convention and mass-versus-molar units when moving between datasets.

A heater example

Assume liquid enters a steady heater at 20°C and leaves at 50°C, with mass flow 0.20 kg/s. Take a specified constant cp of 4.18 kJ/(kg·K), negligible kinetic and potential changes and no shaft work.

The sensible enthalpy increase is about cpΔT = 125.4 kJ/kg. Required heat transfer into the liquid is therefore 0.20 × 125.4 = 25.1 kW.

That is the fluid-side heat requirement. If an electrical heater also loses 2 kW to the room at steady conditions, its electrical input must account for that loss. If the heater and vessel are warming, stored energy introduces a transient term. The same 25.1 kW cannot automatically describe startup.

Distinguish transfer amount from transfer rate

For a plane wall under simple steady one-dimensional conduction, Qdot = kAΔT/L. Convection uses Qdot = hA(Tsurface − Tfluid), with a coefficient tied to flow and geometry. Radiation depends on absolute temperatures and surface interactions.

A 25.1 kW heat requirement does not establish the required heat-transfer area by itself. One also needs driving temperature differences and a valid heat-transfer coefficient or resistance model. The DOE heat-transfer handbook explains these mechanisms and their combination.

Fins create another distinction. More surface area can improve heat transfer, but the added surface is not usually all at the base temperature. Fin efficiency adjusts that ideal area-based estimate.

Compare cycles on a stated basis

Thermal efficiency is net work output divided by heat input to the defined cycle. Carnot efficiency, 1 − TC/TH, is an ideal bound for reservoirs at constant absolute temperatures. Otto, Brayton and Rankine cycles make different process and working-fluid assumptions.

A calculated ideal efficiency is not a measured equipment efficiency. Mechanical losses, component irreversibility, pressure drops, heat leakage and auxiliaries can change the result. Fuel-based plant efficiency also requires the heating-value convention and system boundary.

Use moisture definitions carefully

Humidity ratio uses water-vapor mass per dry-air mass; specific humidity uses water-vapor mass per total moist-air mass. Relative humidity instead compares vapor pressure with saturation vapor pressure at the stated temperature. The ASHRAE psychrometrics chapter defines these quantities and the assumptions behind common moist-air relations.

Pressure must accompany humidity calculations when converting between pressure and mass-ratio descriptions. Mixing grams per kilogram with kilograms per kilogram creates a factor-of-1,000 error.

Continue by task

Read enthalpy, internal energy and heat, cycle efficiency, heat-transfer modes, humidity definitions or the steady-flow workflow.

The energy-equation calculator, Carnot calculator and humidity calculator support those methods once the boundary, state model and units are explicit.

Sources & further reading