Distinguish humidity ratio, specific humidity and relative humidity by mass or pressure basis. Convert definitions and check pressure and saturation inputs.

Humidity ratio and specific humidity both describe water vapor by mass, but they use different denominators. Humidity ratio W is water-vapor mass divided by dry-air mass. Specific humidity q is water-vapor mass divided by the total moist-air mass.

W = mv/mda

q = mv/(mda + mv) = W/(1 + W).

The reverse conversion is W = q/(1 − q). Both are dimensionless mass ratios, often displayed as kg/kg or g/kg. Retain the denominator label when clarity matters.

The ASHRAE psychrometrics chapter defines these quantities separately from relative humidity.

Original mass-basis example

Suppose a sample contains 1.000 kg of dry air and 0.020 kg of water vapor. Humidity ratio is 0.020 kg water/kg dry air, or 20.0 g/kg dry air.

Total moist-air mass is 1.020 kg, so specific humidity is 0.020/1.020 = 0.01961 kg/kg, or 19.61 g/kg moist air. The difference is small in this example but systematic. Using 20 in the kg/kg formula instead of 0.020 would give a completely different result.

For a dry-air mass flow of 0.50 kg/s at this W, vapor mass flow is 0.010 kg/s and total moist-air flow is 0.510 kg/s. A mass flow labeled merely “air” therefore needs its basis identified.

Relate a mass ratio to pressure

Under the usual ideal-gas mixture approximation for ordinary moist air:

W ≈ 0.621945 pv/(p − pv).

Here p is total absolute pressure and pv is vapor partial pressure in the same pressure units. Vaisala's mixing-ratio documentation states a corresponding coefficient in g/kg.

At p = 100 kPa and pv = 2 kPa, W is approximately 0.01269 kg/kg dry air. Specific humidity is then about 0.01253 kg/kg moist air. Using gauge pressure of zero for an ambient sample would make the denominator meaningless.

Relative humidity has another definition

Relative humidity compares vapor partial pressure with saturation vapor pressure at the stated temperature. In a simplified ideal-gas expression, RH = 100 pv/pws(T).

Knowing RH alone does not establish water mass content. Temperature sets saturation pressure, while total pressure enters conversion to W. A 50% RH sample at a warmer temperature can contain much more vapor than a 50% RH sample at a cooler temperature.

Check the saturation convention, especially below freezing, where liquid-water and ice references differ. A single-phase equilibrium moist-air model should also be checked against the saturation limit; condensate changes the mass and energy balance.

Name the quantity on the result

Some software historically labels a dry-air mixing ratio “specific humidity.” Verify the defining equation rather than relying on the field name. Correcting that label can prevent an error larger than adding more numerical precision.

Use the psychrometry calculator after confirming its denominator and pressure basis. The thermodynamics handbook connects humidity ratios with moist-air enthalpy and energy calculations.