Thermodynamics · Guide

Setting up a steady-flow energy balance

Draw a control volume and balance heat, shaft work, enthalpy, velocity and elevation. Apply a consistent sign convention in a worked turbine example.

A steady-flow energy balance accounts for energy crossing a control-volume boundary by heat transfer, work and moving mass. Steady means there is no net accumulation inside the chosen volume. It does not imply zero flow or zero heat transfer.

Begin with a sketch showing every inlet, outlet, heat interaction and shaft. Establish a separate mass balance before reducing the energy equation.

State the convention

Take heat into the control volume as positive and shaft work out as positive. For one inlet and one outlet at equal steady mass flow:

Qdot − Wdot = ṁ[(h2 − h1) + (V2² − V1²)/2 + g(z2 − z1)].

Enthalpy includes flow-work effects; do not add a separate pv term when using h. The DOE thermodynamics handbook develops this form from the first law.

For multiple streams, sum ṁ(h + V²/2 + gz) over all inlets and outlets. A mixer cannot generally be reduced to one arbitrarily selected inlet enthalpy.

Original turbine example

Assume a steady turbine carries 2 kg/s. Inlet enthalpy is 3,200 kJ/kg and outlet enthalpy 2,600 kJ/kg. Inlet speed is 50 m/s and outlet speed 150 m/s. Elevation change is negligible, and heat loss to the room is 20 kW.

With the stated convention, Qdot = −20 kW. The enthalpy term on the right is 2 × (−600) = −1,200 kW. The kinetic-energy increase is:

(150² − 50²)/2 = 10,000 J/kg = 10 kJ/kg.

Multiplying by mass flow gives 20 kW. Therefore:

−20 − Wdot = −1,200 + 20,

so shaft output is 1,160 kW. Neglecting both heat loss and kinetic change would predict 1,200 kW. The differences are traceable to explicit terms.

The enthalpy values here are illustrative inputs, not a calculated steam state. An actual steam calculation needs matching pressure, temperature or quality data and a consistent method such as IAPWS-IF97.

Make simplifications after writing the full balance

An adiabatic device has negligible heat transfer across its boundary; it does not necessarily have constant temperature. A throttling valve with no shaft work and negligible kinetic/potential changes has approximately equal inlet and outlet enthalpy, even though pressure falls.

For a pump using the work-out convention, shaft power is normally negative. It can be clearer to define a positive input-power magnitude afterward, rather than silently switching the sign within the equation.

A nozzle can exchange enthalpy for kinetic energy. Its velocity terms may therefore be the main point of the problem, not a correction to omit.

Check the closure and units

All specific energy terms must use the same units. With SI velocities and elevations, kinetic and potential terms emerge in J/kg. Convert to kJ/kg if the property table uses that scale.

Report whether the control volume includes the motor, generator or surrounding pipework. Those choices change the measured work and heat interactions.

Use the steady-flow energy calculator after defining the boundary and signs. Read enthalpy versus heat if the property and transfer terms remain uncertain.