Material properties · reference

Thermal Properties of Rubbers

Use grade-specific values with their conditions. This compact reference deliberately leaves unsourced properties blank.

MaterialDensity kg/m³Conductivity W/(m·K)Specific heat J/(kg·K)Conditions & source
BISCO HT-800 silicone foam3520.076Not suppliedMedium cellular silicone, typical density 22 lb/ft³. Thermal conductivity 0.076 W/(m·K), ASTM C518. Foam is not interchangeable with solid silicone. Rogers HT-800 technical data sheet

Sourced values for common solid rubbers

Rubber is a family of compounds, so the values below describe the named compound or the generic figure in the cited source. Fillers, plasticiser and cure system shift every property. Specific heat capacity is blank for every row: no manufacturer or standards source for these elastomers was opened for this page.

MaterialDensity kg/m³Thermal conductivity W/(m·K)Specific heat J/(kg·K)Service min °CService max °CGrade and conditions by property
Natural rubber (NR)930 10.15 2Not sourcedNot sourced93.3 1
  • density: Generic NR, TSE typical values; Typical value for dry specimens; temperature not stated
  • conductivity: Vulcanized natural rubber; 25 °C
  • max service: Generic NR, TSE typical values; Maximum temperature as printed; not labelled continuous
Neoprene (CR)1,230 30.19 2Not sourced-40 4121 4
  • density: Generic CR, TSE typical values; Typical value for dry specimens; temperature not stated
  • conductivity: Polychloroprene; 25 °C
  • min service: Marco compound N1000, 70 Shore A; Dry-air service; approximate, not a design limit
  • max service: Marco compound N1000, 70 Shore A; Dry-air service; approximate, not a design limit
Nitrile (NBR)1,000 50.24 2Not sourced-34 6121 6
  • density: Generic NBR, TSE typical values; Typical value for dry specimens; temperature not stated
  • conductivity: NBR; 25 °C
  • min service: Marco compound B1000, 70 Shore A; Dry-air service; approximate, not a design limit
  • max service: Marco compound B1000, 70 Shore A; Dry-air service; approximate, not a design limit
EPDM1,150 7Not sourcedNot sourced-55 8150 8
  • density: Marco compound E1000, 70 Shore A, peroxide cured; Typical test result; temperature not stated
  • min service: Marco compound E1000, 70 Shore A; Dry-air service; approximate, not a design limit
  • max service: Marco compound E1000, 70 Shore A; Dry-air service; approximate, not a design limit
Silicone rubber, solid (VMQ)1,200 90.14 2Not sourced-59 10204 10
  • density: Solid silicone sheet, 40–70 Shore (TYM); Temperature not stated
  • conductivity: Plain "Silicone rubber" row; the article does not say solid or foam; 25 °C
  • min service: Marco compound S1000, 70 Shore A; Dry-air service; approximate, not a design limit
  • max service: Marco compound S1000, 70 Shore A; Dry-air service; approximate, not a design limit
  1. TSE Industries NR properties (accessed 2026-11-24)
  2. Electronics Cooling, thermal conductivity of rubbers (accessed 2026-11-24)
  3. TSE Industries CR properties (accessed 2026-11-24)
  4. Marco Rubber neoprene O-rings (accessed 2026-11-24)
  5. TSE Industries NBR properties (accessed 2026-11-24)
  6. Marco Rubber O-ring material comparison (accessed 2026-11-24)
  7. Marco E1000 datasheet (accessed 2026-11-24)
  8. Marco Rubber EPDM O-rings (accessed 2026-11-24)
  9. TYM solid silicone sheet datasheet (accessed 2026-11-24)
  10. Marco Rubber silicone O-rings (accessed 2026-11-24)

Does rubber conduct heat?

Yes, but poorly. The vulcanised natural, neoprene, nitrile and silicone figures above lie between 0.14 and 0.24 W/(m·K) at 25 °C. Thermtest measured three neoprene sheets at 23 °C with the transient plane source method and reported 0.204 to 0.237 W/(m·K) for 30A to 60A durometer. Pure copper is far higher: Aalco's datasheet lists 391.1 W/(m·K). Rubber therefore slows heat flow, but it is not a perfect insulator, and cellular foams insulate better than solid rubber.

Rubber has no single melting point

A vulcanised rubber is a crosslinked network. University of Washington course notes explain that a crosslinked polymer cannot be melted; if the temperature rises high enough, the bonds break and the material is chemically degraded. A question such as "what temperature does rubber melt" therefore has no single answer. What matters is the service-temperature range, which depends on compound, ageing, fluid and load.

The service limits above are from Marco Rubber compound pages and are stated for dry-air service as approximations, not design limits. The natural-rubber maximum is TSE Industries' printed maximum temperature, not labelled continuous. No natural-rubber low limit is shown because only a brittle point was found, which is a different quantity. EPDM has no sourced conductivity.

Sources & further reading

Cellular and solid rubber behave differently

The silicone-foam entry includes gas-filled cells. Its bulk density and heat-transfer response cannot be substituted for solid silicone rubber. Compression, thickness and temperature affect performance. Thermal conductivity does not establish a safe service temperature or flammability classification.

Use the values together carefully

Thermal diffusivity is k/(ρcp), with compatible conductivity, density and heat-capacity values. Do not combine numbers from unrelated grades to fill a missing cell. When conditions are incompatible, report the result as unavailable until suitable data are obtained.

For a first mass estimate, m = ρV. Volume uncertainty and porosity may matter more than an extra decimal place in the tabulated density.

Compare the sourced materials →

Sources & further reading