Material properties · tool

Compare Material Properties

Compare sourced values and conditions side by side. A missing value means that this reference has not supplied one.

Reference set

MaterialDensity kg/m³Conductivity W/(m·K)Specific heat J/(kg·K)Conditions & source
Copper C11000 (ETP)8,920394Not suppliedCopper Development Association design guide; nominal physical values. Conductivity is a rounded guide value, not an acceptance limit. CDA copper-alloy design guide
TECAFORM AH natural (POM-C)1,4100.391,400Unfilled stock shape. CLTE is longitudinal, 23–60 °C. Conductivity and heat capacity: ISO 22007-4. Typical data, not a specification. Ensinger product data
BISCO HT-800 silicone foam3520.076Not suppliedMedium cellular silicone, typical density 22 lb/ft³. Thermal conductivity 0.076 W/(m·K), ASTM C518. Foam is not interchangeable with solid silicone. Rogers HT-800 technical data sheet

Values are not design allowables. There is no automatic winner: low conductivity may be useful for insulation but undesirable for heat transfer. Read the grade, temperature and measurement conditions before comparing.