Thermal Properties of Polymers
Use grade-specific values with their conditions. This compact reference deliberately leaves unsourced properties blank.
| Material | Density kg/m³ | Conductivity W/(m·K) | Specific heat J/(kg·K) | Conditions & source |
|---|---|---|---|---|
| TECAFORM AH natural (POM-C) | 1,410 | 0.39 | 1,400 | Unfilled stock shape. CLTE is longitudinal, 23–60 °C. Conductivity and heat capacity: ISO 22007-4. Typical data, not a specification. Ensinger product data |
Sourced values for common plastics
Each row is one named product or datasheet grade. Property cells that no opened source supplied for that grade are marked Not sourced; they are not estimated from another plastic. Modulus is the tensile modulus of elasticity in megapascals.
| Material | Density kg/m³ | Thermal conductivity W/(m·K) | Specific heat J/(kg·K) | Tensile modulus MPa | Grade and conditions by property |
|---|---|---|---|---|---|
| Polycarbonate | 1,190 1 | 0.25 1 | 1,300 1 | 2,200 1 |
|
| Polyamide 6 (PA6) | 1,140 2 | 0.37 2 | 1,600 2 | 3,300 2 |
|
| Polypropylene (PP) | 930 3 | Not sourced | Not sourced | 2,000 3 |
|
| PTFE | 2,150 4 | 0.2 4 | Not sourced | Not sourced |
|
| ABS | 1,040 5 | Not sourced | Not sourced | 1,700 5 |
|
| PMMA | 1,190 6 | 0.19 6 | 1,470 6 | 3,300 6 |
|
| PVC, rigid | 1,440 7 | 0.2 7 | Not sourced | 3,000 7 |
|
| HDPE | 950 8 | Not sourced | Not sourced | 1,100 8 |
|
- Ensinger TECANAT natural (accessed 2026-11-24)
- Ensinger TECAMID 6 natural (accessed 2026-11-24)
- Ensinger TECAPRO MT white (accessed 2026-11-24)
- Ensinger TECAFLON PTFE natural (accessed 2026-11-24)
- Ensinger TECARAN ABS grey (accessed 2026-11-24)
- Röhm PLEXIGLAS GS/XT datasheet (accessed 2026-11-24)
- Ensinger PVC datasheet (accessed 2026-11-24)
- SIMONA technical handbook, PE-HD (accessed 2026-11-24)
Modulus of elasticity of polycarbonate
The Ensinger TECANAT natural datasheet gives a tensile modulus of 2,200 MPa, measured at 1 mm/min to DIN EN ISO 527-2. Treat that as a short-term value for one unfilled grade. Glass-filled grades are stiffer, and loading rate, temperature and moisture change a plastic's modulus. For comparison the same table gives 3,300 MPa for PLEXIGLAS PMMA (short-term) and 3,300 MPa for TECAMID 6 natural (PA6).
Thermal conductivity, specific heat and modulus are different properties and are not interchangeable. Rigid PVC, HDPE, polypropylene, PTFE and ABS rows that lack a specific-heat value are blank because the datasheets opened for this page did not report one in SI units.
Match the grade and direction
The listed POM-C values describe one unfilled stock-shape product. Filled grades, processing direction, conditioning and temperature can change thermal response. The expansion coefficient is supplied for a specific interval and direction; do not extend it to a wider interval without supporting data.
Use the values together carefully
Thermal diffusivity is k/(ρcp), with compatible conductivity, density and heat-capacity values. Do not combine numbers from unrelated grades to fill a missing cell. When conditions are incompatible, report the result as unavailable until suitable data are obtained.
For a first mass estimate, m = ρV. Volume uncertainty and porosity may matter more than an extra decimal place in the tabulated density.
Compare the sourced materials →Sources & further reading
- ensingerplastics.com shapes / acetal-tecaform-ah-natural
- ensingerplastics.com shapes / polycarbonate-tecanat-natural
- ensingerplastics.com shapes / pa6-tecamid-6-natural
- ensingerplastics.com shapes / pp-medical-tecapro-mt-white
- ensingerplastics.com shapes / tecaflon-ptfe-natural
- ensingerplastics.com shapes / tecaran-abs-grey
- plexiglas.de technische-informationen / 211-1-EN-PLEXIGLAS-GS-XT.pdf
- ensingerplastics.com uk-documents / datasheet-pvc-en.ashx