Material properties · reference

Material Density Reference

Use grade-specific values with their conditions. This compact reference deliberately leaves unsourced properties blank.

MaterialDensity kg/m³Conductivity W/(m·K)Specific heat J/(kg·K)Conditions & source
Copper C11000 (ETP)8,920394Not suppliedCopper Development Association design guide; nominal physical values. Conductivity is a rounded guide value, not an acceptance limit. CDA copper-alloy design guide
TECAFORM AH natural (POM-C)1,4100.391,400Unfilled stock shape. CLTE is longitudinal, 23–60 °C. Conductivity and heat capacity: ISO 22007-4. Typical data, not a specification. Ensinger product data
BISCO HT-800 silicone foam3520.076Not suppliedMedium cellular silicone, typical density 22 lb/ft³. Thermal conductivity 0.076 W/(m·K), ASTM C518. Foam is not interchangeable with solid silicone. Rogers HT-800 technical data sheet

Density is a measured material property

A family label such as metal, polymer or rubber does not identify one density. For a known specimen, calculate density from measured mass and volume. For a design estimate, identify the grade and condition before using a table value.

Use the values together carefully

Thermal diffusivity is k/(ρcp), with compatible conductivity, density and heat-capacity values. Do not combine numbers from unrelated grades to fill a missing cell. When conditions are incompatible, report the result as unavailable until suitable data are obtained.

For a first mass estimate, m = ρV. Volume uncertainty and porosity may matter more than an extra decimal place in the tabulated density.

Compare the sourced materials →

Sources & further reading