Welding energy per length combines electrical arc power with travel speed. Whether the reported quantity includes a process-efficiency factor must be stated. TWI's arc-energy and heat-input guidance distinguishes the quantities and notes that terminology can vary across codes and regions.
For approximately steady voltage V and current I, electrical power is VI watts, or joules per second. Divide by travel speed in length per second to obtain joules per length.
Use the correct speed conversion
With travel speed v in mm/min:
Arc energy = 60VI/(1000v) kJ/mm.
If v is already in mm/s:
Arc energy = VI/(1000v) kJ/mm.
Multiplying by 60 in the second expression would overstate the result by sixty. When a process-efficiency convention is required:
Heat input = η × arc energy.
The efficiency belongs to the specified process and reporting method. It should not be selected merely to bring a result inside a desired range.
Original worked example
Assume measured steady values of 25 V and 160 A, with a travel speed of 240 mm/min. Electrical arc power is 4,000 W.
Arc energy is 60 × 25 × 160/(1000 × 240) = 1.00 kJ/mm. If the applicable calculation explicitly uses an efficiency factor of 0.80, the adjusted heat input is 0.80 kJ/mm.
The same travel speed is 4 mm/s. Using that speed gives 4000/(1000 × 4) = 1.00 kJ/mm, confirming the conversion.
For a 120 mm run at the stated steady conditions, arc-on time is 30 s. Electrical energy is 120 kJ. Dividing by 120 mm again gives 1.00 kJ/mm. This independent energy-over-length check is useful when a spreadsheet has several unit conversions.
Measure the actual run
TWI's parameter-measurement guidance identifies current, arc voltage and travel speed as key recorded parameters. Machine dial settings and open-circuit voltage are not automatically the values during welding.
Travel speed uses the length deposited during the relevant arc-on period. Shift duration, electrode-change time and repositioning delays are different quantities. A weave pattern also requires a clear convention for run length and speed.
For pulsed or waveform-controlled processes, the average of instantaneous power need not equal average voltage multiplied by average current. When voltage and current vary together, average(VI) is the appropriate electrical-power quantity. Measurement and procedure requirements determine the acceptable method.
Keep energy per length within its scope
Identical energy per length does not guarantee identical weld geometry, cooling history, toughness or distortion. Material thickness, joint design, preheat, interpass temperature, process and heat distribution also matter.
A calculator result does not replace a qualified welding procedure or establish acceptable limits for an unspecified material. State the definition, measured inputs, process factor and units in the record.
Use the welding heat-input calculator with its explicit convention. Return to the manufacturing handbook for the distinction between process estimates and equipment or procedure limits.