Manufacturing · calculator

Welding Heat Input Calculator

Heat input in kJ/mm = η × V × I ÷ (1000 × v), with travel speed v in mm/s. 24 V, 200 A at 5 mm/s with η = 0.8 gives 0.768 kJ/mm.

The model

H = ηVI/v

Enter your values

Units shown per input
Your result

Enter values and select Calculate.

Reproducible example

Work through the default case

The example uses these inputs. Replace them with your own values only after checking the model assumptions.

InputValueUnit
Thermal efficiency fraction0.8dimensionless
Arc voltage20V
Welding current100A
Travel speed5mm/s
Net heat input
0.32 kJ/mm
Arc energy per length
0.4 kJ/mm

These values show the equation in use. They are not recommended operating conditions or material specifications.

The formula and its symbols

Arc energy is the energy the arc delivers per unit weld length before any efficiency is applied. Heat input multiplies it by the process efficiency:

Arc energy = V I / (1000 v) [kJ/mm]
Heat input HI = η × V I / (1000 v) [kJ/mm]

If speed is logged in mm/min, divide it by 60 first, or use HI = 0.06 η V I / v with v in mm/min.

Which efficiency factor?

TWI tabulates efficiency factors for arc processes. All of them are expressed relative to submerged arc welding:

Processη
Submerged arc (SAW)1.0
Manual metal arc / shielded metal arc0.8
Flux-cored arc0.8
MAG / MIG / gas metal arc0.8
TIG / gas tungsten arc0.6
Plasma arc0.6

Laser and electron-beam welding do not set up an arc between the source and the workpiece, so these factors do not apply. TWI notes that the efficiency of power-beam processes depends on the power intensity, and that laser heat input is written without an efficiency factor. The calculator's arithmetic is not meant for those processes.

Heat input or arc energy?

TWI points out that some American codes use "heat input" for what Europe calls arc energy. The calculator reports both so that you can match the definition your code or procedure uses. TWI also notes that Europe typically quotes kJ/mm and America kJ/in; multiply kJ/mm by 25.4 to get kJ/in.

Worked example

Two weld records

MAG weld. 24 V, 200 A, 300 mm/min. Speed in mm/s is 300 ÷ 60 = 5. Arc energy = 24 × 200 ÷ 5 ÷ 1000 = 0.960 kJ/mm. With η = 0.8, heat input = 0.768 kJ/mm, or 19.5 kJ/in.

TIG weld. 12 V, 150 A, 120 mm/min, so v = 2 mm/s. Arc energy = 12 × 150 ÷ 2 ÷ 1000 = 0.900 kJ/mm. With η = 0.6, heat input = 0.540 kJ/mm.

A frequent slip is entering 300 as mm/s. The result would be 0.016 kJ/mm, 60 times too small.

Assumptions and limits

Common mistakes

Frequently asked questions

What is the heat input formula in welding?

Heat input = η × V × I ÷ (1000 × v) in kJ/mm, with voltage in volts, current in amperes and travel speed in mm/s.

What is the difference between heat input and arc energy?

Arc energy is V I / v before efficiency. Heat input applies the process efficiency, so it is the energy that reaches the workpiece.

Which efficiency should I use for MIG welding?

TWI lists 0.8 for MAG/MIG/gas metal arc welding. Check whether your governing procedure specifies a different factor.

What units does welding heat input use?

kJ/mm in Europe and kJ/in in America, according to TWI. Multiply kJ/mm by 25.4 for kJ/in.

Does heat input include preheat?

No. It describes the energy supplied by the arc per unit length of weld only.

Related pages

Welding heat input: units, speed and efficiency walks through the unit conventions. The energy density calculator covers energy per unit volume.

Sources & further reading