Manufacturing · Guide

Flow stress and strain hardening

Use a true-plastic-strain hardening law within its fitted range. Distinguish current flow stress, average flow stress and ideal plastic-work estimates.

Flow stress is the stress required to continue plastic deformation under specified conditions. It can vary with strain, strain rate, temperature and material history. In a simple strain-hardening model:

σflow = K εp^n,

K is a fitted strength coefficient, εp is true plastic strain and n is a hardening exponent. The equation must retain the strain definition and test range used in the fit.

MIT's plastic-flow notes provide the broader yield and plasticity context.

Current and average flow stress differ

Current flow stress is the value at the present strain. Average flow stress over a strain interval is the plastic work per volume divided by that interval:

σaverage = [1/(ε2 − ε1)] ∫ε1^ε2 σflow dεp.

For a power law integrated from zero to εf, this becomes:

σaverage = K εf^n/(n + 1).

NPTEL's forming exercise uses the average-flow-stress concept. The averaging divisor is essential; the integral alone is energy per volume, not an average stress.

Original hardening example

Assume a hypothetical fitted law has K = 600 MPa and n = 0.20. At true plastic strain 0.30, current flow stress is:

600 × 0.30^0.20 = 472 MPa.

The average from zero to 0.30 is about 472/1.20 = 393 MPa. Ideal plastic work per volume is 393 × 0.30 = 118 MPa, numerically 118 MJ/m³ because Pa = J/m³.

For a deforming material volume of 1.0 × 10⁻⁵ m³, the ideal plastic work would be about 1.18 kJ. Friction, nonuniform deformation and other losses can increase actual process work.

These values illustrate a fitted law, not a named material's forming properties.

Use the appropriate strain

For uniform uniaxial length change, true total strain is ln(L/L0). True plastic strain separates out elastic strain under the relevant assumptions. Engineering strain and true strain differ at finite deformation, so a law fitted with one cannot silently be evaluated with the other.

A homogeneous compression reduction from initial height h0 to final height hf uses a compressive true-strain magnitude ln(h0/hf). For a 30% height reduction, hf = 0.70h0 and the magnitude is 0.357. The percentage reduction itself, 0.30, is not that logarithmic strain.

Recognize fit limits

The pure power law approaches zero stress as strain approaches zero for positive n. That mathematical behavior does not prove zero initial yield strength. Some fits use a prestrain offset or a separate initial-yield term.

Hot forming may need temperature and strain-rate dependence, while anisotropic sheet forming requires more than an isotropic scalar law. Necking and fracture also limit usable deformation.

Use the flow-stress calculator only with a defined law and qualified constants. The stress-strain guide explains the conversion and localization issues behind those inputs.