Manufacturing · Guide

Cutting force, spindle power and material removal rate

Relate cutting force to net spindle power and material removal rate. Distinguish turning and milling inputs, feed conventions and machine efficiency.

Cutting force, power and removal rate describe related aspects of machining, but none determines the others without a process model. Force times cutting speed gives a mechanical power component. Removal rate gives volume per time. Connecting volume removal to power needs a suitable specific cutting energy or force model.

Sandvik's turning formulas and milling formulas distinguish process inputs and their units.

Start with the direct power balance

If a tangential cutting force Fc acts at cutting speed vc:

Pc = Fc vc.

With force in N and speed in m/s, power is W. If speed is in m/min, divide by 60. A speed of 120 m/min is 2 m/s, so a 600 N cutting-force component corresponds to 1.20 kW.

This is net cutting power for that component. Electrical input to the machine includes drive and other losses. A force measured in a feed direction cannot automatically be paired with the much larger tangential cutting speed.

Calculate process-specific removal rate

For a simple milling engagement:

Q = ae ap vf,

with width ae and depth ap in mm and table feed vf in mm/min, giving mm³/min. Divide by 1,000 for cm³/min.

For turning, a commonly used compact metric relation is Q = vc ap fn in cm³/min when vc is m/min and depth ap and feed per revolution fn are mm. The mixed-unit cancellation is built into that expression.

A milling feed per tooth must first be converted using vf = fz n zeff. Using feed per tooth directly as table feed loses rotation speed and tooth count.

Original power and force comparison

Assume a turning estimate uses vc = 150 m/min, ap = 2 mm and fn = 0.20 mm/rev. Removal rate is 60 cm³/min.

With an illustrative appropriate specific cutting force kc = 1,800 N/mm², nominal tangential force is kc ap fn = 720 N. Cutting speed is 2.5 m/s, so net power is 1.80 kW.

The equivalent volume-based calculation is 60 × 1800/60,000 = 1.80 kW. If drive efficiency from electrical input to cutting power were assumed to be 0.80, the associated input would be 2.25 kW before unrelated auxiliaries. This efficiency is a stated example, not a machine rating.

Do not treat kc as universally constant

Specific cutting force depends on material and chip conditions. Tool geometry, chip thickness, edge effects and wear can change the relationship. Manufacturer data can include corrections, and a simple average-force estimate will not reproduce every peak load in interrupted cutting.

Machine capability must be checked at the actual spindle speed. A motor can have enough nominal power while available low-speed torque or tool-holder capacity remains limiting. Chatter and workholding are also outside a scalar power equation.

Use cutting force and material removal rate tools with a matching process definition. Read machining-data selection before borrowing coefficients or feeds from a table.

Sources & further reading