Material properties · reference

Electrical Properties of Metals

Electrical resistivity and conductivity are reciprocal material properties. Their values change with composition, processing and temperature.

A sourced metal reference

GradeConductivityDerived resistivitySource condition
Copper C11000 (ETP)58 MS/m≈ 1.724 × 10⁻⁸ Ω·mCopper Development Association design guide; nominal physical values. Conductivity is a rounded guide value, not an acceptance limit. CDA guide

The resistivity is calculated as 1 / (58 × 10⁶). It inherits the rounding and applicability of the source conductivity. This is not a minimum conductivity requirement for every product sold under that designation.

Sourced resistivity at a stated temperature

Resistivity ρ is in ohm metres. Conductivity is calculated as 1/ρ and shown in MS/m, so it carries the same uncertainty and temperature as the source value. A range means the source printed a range; neither end is a minimum or acceptance limit. Rows from datasheets that give no temperature say so. Pure-element values from the HyperPhysics table are for 20 °C. Commercial alloys vary with composition and temper.

Material, gradeResistivity Ω·mConductivity MS/m (calculated, 1/ρ)Temperature
Aluminium 6061
6061-T6 extrusions, BS EN 755-2
4 × 10−8 125Temperature not stated by the source
Stainless steel 304
1.4301 (304) bar and section, EN 10088-3
7.2 × 10−7 21.39Temperature not stated by the source
Stainless steel 316
1.4401 (316) bar and section, EN 10088-3
7.4 × 10−7 31.35Temperature not stated by the source
Brass CW614N
CW614N rod, EN 12164
6.2 × 10−8 416.1Temperature not stated by the source
Copper CW004A
CW004A (pure copper) sheet, plate and bar
1.71 × 10−8 558.5Temperature not stated by the source
Silver
Element, purity not stated
1.59 × 10−8 662.920 °C
Aluminium (pure)
Element, purity not stated
2.65 × 10−8 637.720 °C
Tungsten
Element, purity not stated
5.6 × 10−8 617.920 °C
Iron (pure)
Element, purity not stated
9.71 × 10−8 610.320 °C
Lead
Element, purity not stated
2.2 × 10−7 64.5520 °C
Carbon steel
EN C45 (1.0503), Ovako material data sheet
2 × 10−7 to 2.5 × 10−7 74 to 5"Ambient temperature"; range as printed
Aluminium 7075
7075-T6, NASA Materials Data Handbook
5.2 × 10−8 819.220 °C
Titanium Ti-6Al-4V
Grade 5, Upmet datasheet
1.71 × 10−6 90.58568 °F (20 °C)
Gold
Foil (Goodfellow)
2.2 × 10−8 1045.520 °C
Nickel
Nickel 200/201, ATI datasheet
8.5 × 10−8 1111.827 °C (80 °F), not 20 °C; one table for both ATI 200 and ATI 201
  1. Aalco datasheet, Al 6061-T6 (accessed 2026-11-24)
  2. Aalco datasheet, 1.4301 (304) (accessed 2026-11-24)
  3. Aalco datasheet, 1.4401 (316) (accessed 2026-11-24)
  4. Aalco datasheet, brass CW614N (accessed 2026-11-24)
  5. Aalco datasheet, copper CW004A (accessed 2026-11-24)
  6. HyperPhysics resistivity table (accessed 2026-11-24)
  7. Ovako Steel Navigator, C45 (accessed 2026-11-24)
  8. NASA Materials Data Handbook, aluminium alloy 7075 (accessed 2026-11-24)
  9. Upmet Ti-6Al-4V datasheet (accessed 2026-11-24)
  10. Goodfellow gold foil (accessed 2026-11-24)
  11. ATI Nickel 200/201 datasheet (accessed 2026-11-24)

Nickel is quoted at 27 °C because that is the temperature in the source table. Carbon steel is shown as the range printed by the source.

From a material value to resistance

For a uniform conductor, R = ρL/A. A 1 m conductor with 1 mm² area and the reference resistivity above gives approximately 0.01724 Ω. Real connections add contact resistance; AC operation can introduce skin and proximity effects.

Comparing other metals

Use the specific alloy data sheet, temperature and condition. Pure-element values do not stand in for a commercial steel or aluminium alloy. Keep conductivity, resistivity and total component resistance in separate columns.

Convert resistivity units →

Sources & further reading