For a small opening discharging an incompressible liquid from a large reservoir, a common model is:
Q = Cd A sqrt(2Δp/ρ), or Q = Cd A sqrt(2gh).
The head h represents the relevant pressure/elevation head driving the discharge. The coefficient Cd adjusts an ideal prediction for the actual geometry and flow behavior. It is not a fluid property.
Define the physical arrangement
For a free jet from a large tank, the upstream free-surface speed can often be neglected. When the tank surface and jet are at the same ambient pressure, the vertical distance from surface to opening provides h.
A submerged outlet instead depends on the difference between the upstream and downstream heads. A pressurized tank requires the pressure contribution too. The head is not automatically the water depth on just one side of the opening.
The Bureau of Reclamation's orifice relationships describe contraction after a sharp-edged opening. A jet's narrowest section can be smaller than the physical hole, which helps explain why actual discharge differs from the ideal area-times-speed estimate.
Worked estimate
Assume a circular hole with diameter 10 mm, driving head 0.8 m and a specified illustrative Cd of 0.62. The hole area is 7.854 × 10⁻⁵ m². With g = 9.81 m/s²:
Q = 0.62 × 7.854 × 10⁻⁵ × sqrt(2 × 9.81 × 0.8).
The predicted flow is about 0.000193 m³/s, or 0.193 L/s. Using Cd = 1 would give 0.311 L/s. That comparison shows the importance of the coefficient; it does not establish that 0.62 is suitable for every hole.
At otherwise fixed conditions, quadrupling head doubles flow in this model. Doubling hole diameter multiplies area, and therefore flow, by four. Those scaling checks provide quick tests of a calculator result.
Select the coefficient from matching evidence
Record edge shape, plate thickness, approach arrangement, Reynolds number and whether the opening is fully contracted. Manufacturer calibration or a suitable measurement standard can supply an applicable coefficient. A coefficient borrowed from an unrelated valve or rounded nozzle may be misleading.
A pipe-mounted differential-pressure orifice meter has additional geometry, pressure-tap and approach-flow requirements. Its equation may include the diameter-ratio term 1/sqrt(1 − β⁴) and, for gases, expansibility treatment. It should not be reduced to the reservoir equation without checking the derivation.
Recognize limits of the simple model
The calculation assumes a single liquid phase and an appropriate pressure difference. Cavitation can occur when local pressure drops sufficiently, and gas flow may choke. Flashing, two-phase discharge and highly viscous flow need other methods.
If the reservoir drains, h changes with time. A single fixed-head result is an instantaneous discharge estimate. Total drain time requires a transient volume balance with tank geometry.
The DOE fluid-flow handbook supplies the wider continuity and energy framework. Use the orifice tool with an explicitly justified coefficient, and read pressure definitions before supplying a gauge or absolute pressure value.