Aerospace · calculator

Electron Debye Length

Estimate electrostatic screening length for a classical plasma using electron temperature and number density.

The model

λD = √(ε₀ kB Te/(ne e²))

Enter your values

Units shown per input
Your result

Enter values and select Calculate.

Reproducible example

Work through the default case

The example uses these inputs. Replace them with your own values only after checking the model assumptions.

InputValueUnit
Electron temperature10,000K
Electron number density10,000,000,000,000,0001/m³
Electron Debye length
0.00006900898 m

These values show the equation in use. They are not recommended operating conditions or material specifications.